Cracked Heat Exchanger

A cracked heat exchanger can let combustion gases, including carbon monoxide, into the air your furnace sends through the house. Treat it as stop-and-inspect: the furnace stays off until someone has looked.

  • Written estimate first
  • Parts and labor warranty
  • 24/7 phone support

A furnace’s heat exchanger is the sealed metal chamber, or set of tubes, where the burner flame and its exhaust heat the metal. The blower pushes house air across the outside of it, while the combustion gases stay inside and leave through the vent pipe. A crack or hole breaks that separation. It can let combustion gases, including carbon monoxide (CO), reach the air you breathe, and air from the blower can push through the opening and disturb the flame. That is why a suspected crack is a safety problem first and a repair question second: the furnace stays off until it has been inspected.

If a CO alarm is sounding now

  1. Get everyone out of the house, pets included. Don’t stop to look for the cause.
  2. Call 911 from outside.
  3. Stay out until the responders say it is safe to go back in.
  4. Tell the dispatcher if anyone has a headache, dizziness, nausea or confusion. Those are symptoms of CO exposure.
  5. Leave the furnace off afterwards. Never restart a furnace with a suspected cracked heat exchanger, and never restart one that has been shut off and tagged as unsafe.

If you smell gas instead, the order is the same: leave first, then call the gas utility or 911 from outside.

Signs that point to the heat exchanger

What you noticeWhat it may meanWhat it takes
CO alarm sounds while the furnace runsCombustion gases reaching the rooms: heat exchanger, vent or burner problemEvacuate, then a full inspection with CO readings
Soot or dark streaks around the burner areaIncomplete combustion, or flame escaping the burnersBurner, vent and heat exchanger inspection
Yellow, lazy or flickering flame instead of steady bluePoor combustion, or air entering through a breachCombustion check and camera inspection
Flame shifts or wavers the moment the blower startsBlower air reaching the flame through an openingCamera inspection of the heat exchanger
A sharp, unusual odor when the furnace runsCombustion byproducts in the airflowFurnace off until inspected
Headaches or nausea at home that ease once you leavePossible CO exposureLeave, call 911, furnace off
Crack seen during a maintenance visitA confirmed breachNew heat exchanger or new furnace

Why heat exchangers crack

  • Age and thermal stress. Every heating cycle expands the metal and every pause lets it shrink. Over many years the metal fatigues, usually at seams, bends and welds. This is normal wear, and it is one reason an inspection matters more once a furnace is past about 15 years old.
  • Overheating from restricted airflow. A clogged filter, closed registers or a return that is too small let the metal run hotter than it was designed for. A furnace that keeps tripping its high-limit switch, as described on our furnace short cycling page, is overheating.
  • Improper sizing. A furnace too large for the house cycles on and off more often, and one too large for its ducts runs hot.
  • Poor maintenance history. Dirty burners and a flame no one has looked at in years add stress.
  • Manufacturing defect. Occasionally a design is weak, which is when the warranty paperwork matters.

How a crack is confirmed

Most cracks can’t be seen from outside the cabinet, so a CO alarm that stays quiet does not prove the heat exchanger is sound. A technician looks inside with a camera or by removing the burners, watches the flame as the blower starts, and measures CO in the flue gas and at the supply registers. A crack is a serious finding and an expensive one, so you should see the evidence: an image of the crack and where it is, or the readings that point to it. We explain what we found and why. If you want a second opinion before you replace a furnace, that is a reasonable request.

Repair or replace

Patching or sealing a crack is not an accepted repair. The choice is a new heat exchanger or a new furnace. Heat exchangers often carry a longer manufacturer’s warranty than the rest of the furnace, so find the model number, serial number and install date before deciding. Even when the part is covered, the labor is substantial, and on an older furnace a furnace replacement usually makes more sense. Our repair-or-replace guide walks through how to weigh it.

What you can do, and what you shouldn’t

You can:

  • Keep CO alarms on every floor and near the bedrooms, and test them.
  • Look, without opening anything, for soot, scorch marks or rust flakes around the furnace and its vent pipe.
  • Watch the burner flame through the viewing window if your furnace has one. Steady and mostly blue is normal.
  • Keep the filter clean, and ask for a heat exchanger inspection at each furnace tune-up.

Don’t:

  • Run the furnace “just to check” once a crack is suspected.
  • Remove the burner cover or run the furnace with its panels off.
  • Heat the house with a gas oven or range while you wait. Use electric space heaters, kept clear of curtains and bedding.

Local note

In much of Daly City the furnace sits in the ground-floor garage with bedrooms directly above it, and in many mid-century homes that furnace is decades old. Put CO alarms in the rooms over the garage, not only in a hallway at the far end of the house.

Before you book

Can I keep using my furnace if the heat exchanger might be cracked?

No. Keep it off until it has been inspected, because a crack can let carbon monoxide into the air you breathe. Use electric space heaters in the meantime, never a gas oven or range.

Can a cracked heat exchanger be repaired?

Patching or sealing a crack is not an accepted repair. The choice is a new heat exchanger or a new furnace, so check the manufacturer's warranty on the heat exchanger before deciding.

My CO alarm is quiet. Does that mean the heat exchanger is fine?

Not necessarily. Most cracks can't be seen from outside the cabinet and don't always release CO into the rooms, so a camera inspection and combustion readings are what confirm or rule out a crack.

What should I do if the CO alarm goes off?

Get everyone out, pets included, and call 911 from outside. Stay out until responders say it is safe, and leave the furnace off until it has been inspected.