Heat Pump Not Heating in Winter

A heat pump that is not heating is sometimes set up wrong rather than broken: a thermostat in the wrong mode, air that feels cooler than a furnace's, or a defrost cycle in progress. When it really is a fault, the reversing valve, the defrost controls, the refrigerant charge and the backup heat are the usual suspects.

  • Written estimate first
  • Parts and labor warranty
  • 24/7 phone support

A heat pump that is not keeping the house warm in winter is not always broken. A thermostat in the wrong mode, an ordinary defrost cycle or the normal feel of heat pump air can explain it. When something has failed, it is usually the reversing valve, the defrost controls, the refrigerant charge, the compressor or the backup heat. A few checks tell the two situations apart.

Is it actually broken?

  • The air feels lukewarm. A heat pump moves a large volume of warm air rather than the hot blast of a gas furnace. If the house is slowly reaching the setting, the system is working.
  • It blew cool air for a few minutes, then went back to normal. That was most likely a defrost cycle; the page on a frozen heat pump shows what a normal one looks like.
  • It takes hours to recover after a deep night setback. Heat pumps work at a steady pace and do not catch up quickly, and a big setback can bring on the costlier backup heat. Smaller setbacks usually work better.

Thermostat settings that cause “no heat”

  • Mode. It should read Heat, not Cool, Off or Fan. In Auto, the switch between heating and cooling depends on two set points, and a narrow gap between them can make the system flip modes.
  • Aux and Em. Aux heat on the display means the backup is helping because the heat pump cannot keep up alone: normal for a while, not for hours on end. Em heat means the heat pump is switched off and the house is running on backup only.
  • After a thermostat replacement. Heat pump thermostats have a setting for the reversing valve, often labeled O or B, that must match the equipment. Set wrong, the system cools when you ask for heat. If the trouble began the day a new thermostat went in, check this first.
  • Schedules and power cuts. An outage can reset a program and leave the system on a schedule you did not choose.

Symptom, likely cause, what it takes

What you noticeLikely causeWhat it usually takes
Cool air in heat mode, outdoor unit running steadilyReversing valve stuck in cooling, or the thermostat’s O/B setting is wrongThermostat setup check, then valve and solenoid diagnosis
Outdoor unit encased in iceDefrost control, sensor, fan motor or low chargeDefrost and fan diagnosis
Aux heat on constantly, bills climbingHeat pump losing capacity: low charge, dirty coil, weak compressorCharge and performance testing
Outdoor unit not running at allTripped breaker, failed contactor or capacitor, control faultElectrical diagnosis
Outdoor unit hums, then the breaker tripsCompressor failing to startStart components and compressor testing
No warm air even on Em heatAir handler power, backup heat elements, a limit switch or the control boardAir handler and backup heat repair
Warm air, but weak at every ventClogged filter, dirty indoor coil, blower problemFilter, coil cleaning, blower repair

Checks you can make safely

  1. Set the thermostat to Heat, two or three degrees above room temperature, and wait ten minutes.
  2. Replace the filter if it is dirty.
  3. Look at the outdoor unit: is the fan turning, and is there heavy ice? A light, even frost is fine.
  4. Check the breakers. Many systems have one for the outdoor unit and a separate one for the indoor air handler, which also feeds the backup heat.
  5. Try Emergency Heat for a few minutes. If warm air comes out, the indoor side and the backup work, and the fault is on the heat pump side. If nothing warms on Em heat either, the indoor unit or its power is the place to look. Switch back afterwards, because backup heat costs more to run.

What needs a technician

Call when the outdoor unit is fully iced or never defrosts, when you suspect the reversing valve, when you hear hissing or see oily residue on the lines, when a breaker trips twice, or when the backup heat does not work either. Valves, defrost boards, refrigerant and compressors need gauges, electrical meters and EPA-certified technicians for refrigerant handling. On a heat pump repair visit you hear what was found and why, with a written estimate before work starts. If the thermostat itself is the problem, a correctly configured thermostat installation fixes it.

The coastal angle

Heat pumps suit this climate. Winters here are mild and damp rather than cold, so a heat pump spends most of its hours in the outdoor temperatures where it works most efficiently. That also makes a fault easier to spot: a heat pump that cannot hold a normal setting on a 50-degree day in Daly City is not up against the weather. Because heating is needed in most months here, a weakening heat pump leans on backup heat for much of the year, and it often shows up as high energy bills before the house feels cold. Ductless heat pumps in additions and ADUs follow the same logic; see mini-split repair.

Before you book

Why does my heat pump blow cold air in heat mode?

For a few minutes at a time it is probably a defrost cycle, which is normal. If it blows cool air steadily while the outdoor unit runs, the reversing valve may be stuck, or a thermostat's reversing-valve setting may be wrong, especially if the thermostat was recently replaced.

What is the difference between Aux heat and Em heat?

Aux heat means the backup is helping the heat pump automatically, which is normal for short periods. Em heat means the heat pump has been switched off and the house is running on backup alone, usually by a manual setting.

Why is the air from my heat pump only lukewarm?

Heat pumps deliver a larger volume of warm air rather than the hot blast of a gas furnace. If the house slowly reaches the setting, the system is working. If it never does on a mild day, it needs checking.

Should I use a big night setback with a heat pump?

Smaller setbacks usually work better. After a deep setback a heat pump recovers slowly and may call in the backup heat, which costs more to run.